Comparison of fibulin-3 and mesothelin as markers in malignant mesothelioma

Thorax. 2014 July 18. [Epub ahead of print] [Link]

Creaney J, Dick IM, Meniawy TM, Leong SL, Leon JS, Demelker Y, Segal A, Bill Musk AW, Lee YC, Skates SJ, Nowak AK, Robinson BW.

Abstract

Background

Pleural malignant mesothelioma (MM) is a deadly tumour predominantly associated with asbestos exposure. A reliable diagnostic and prognostic marker for MM will significantly enhance clinical care and is an area of intense research. Soluble mesothelin is the most studied and an FDA-approved biomarker for MM. A recent report showed promising results using fibulin-3 as a new diagnostic marker. The aim of this study was to compare the utility of fibulin-3 versus mesothelin, singly or in combination.

Methods

Fibulin-3 and soluble mesothelin were determined by ELISA in the plasma and pleural fluid of 153 patients presenting with a pleural effusion including 82 with MM, 36 with non-MM malignant effusions and 35 with benign effusions. Biomarker concentrations were determined in the plasma of an additional 49 cases with benign asbestos-related disease.

Results

Mesothelin provides better diagnostic accuracy than fibulin-3 for MM whether measured in plasma or pleural effusion: area under the curve (AUC) for plasma was 0.822 (95% CI 0.76 to 0.87) compared with 0.671 (0.61 to 0.73), respectively, and for pleural fluid AUC was 0.815 (0.74 to 0.87) compared with 0.588 (0.51 to 0.67), respectively. Effusion fibulin-3 was an independent significant prognostic factor for survival in MM patients; HR 2.08 (1.14 to 3.82), p=0.017. MM patients with effusion fibulin-3 levels below the median survived significantly longer than those with levels above the median (14.1 vs 7.9 months, p=0.012). Mesothelin and neutrophil to lymphocyte ratio were not significant prognostic markers.

Conclusions

Soluble mesothelin is a superior diagnostic biomarker for MM compared with fibulin-3, whereas fibulin-3 provides superior prognostic information compared with mesothelin.